PS310-2.5V-08-LI2UPN8-H1141Pressure sensor Relative pressure: -1 … 2.5 bar100001520Communication protocolIO-LinkElectrical outputSwitching output, Current output (3-wire), Voltage output (3-wire), IO-LinkProcess connectionG 1/2″ male thread DIN 3852-E (manometer)Pressure range-1...2,5 bar
FP100-300L-04-NA-H1141Flow Sensor Immersion Sensor without Integrated Processor100001045Immersion depth (mm)16.9
PS310-0V-05-LI2UPN8-H1141Pressure sensor Relative pressure: -1 … 0 bar100001489Communication protocolIO-LinkElectrical outputSwitching output, Current output (3-wire), Voltage output (3-wire), IO-LinkProcess connection7/16″-20 UNF male threadPressure range-1...0 bar
PS510-600-08-2UPN8-H1141Pressure sensor Relative pressure: 0 … 600 bar100001750Communication protocolIO-LinkElectrical output2 x switching output, IO-LinkProcess connectionG 1/2″ male thread DIN 3852-E (manometer)Pressure range0...600 bar
PS510-40V-03-LI2UPN8-H1141Pressure sensor Relative pressure: -1 … 40 bar100001561Communication protocolIO-LinkElectrical outputSwitching output, Current output (3-wire), Voltage output (3-wire), IO-LinkProcess connection1/4″ NPT-18 male threadPressure range-1...40 bar
PS310-1V-08-2UPN8-H1141Pressure sensor Relative pressure: -1 … 1 bar100001647Communication protocolIO-LinkElectrical output2 x switching output, IO-LinkProcess connectionG 1/2″ male thread DIN 3852-E (manometer)Pressure range-1...1 bar
PS311-100-09-LI2UPN8-H1141Front-Flush Pressure Sensor Relative pressure: 0 … 100 bar100001578Communication protocolIO-LinkElectrical outputSwitching output, Current output (3-wire), Voltage output (3-wire), IO-LinkProcess connectionG 1/2″ male thread, front-flushPressure range0...100 bar
PS311-250-06-LI2UPN8-H1141Front-Flush Pressure Sensor Relative pressure: 0 … 250 bar100001589Communication protocolIO-LinkElectrical outputSwitching output, Current output (3-wire), Voltage output (3-wire), IO-LinkProcess connectionG 3/4″ male thread, front-flushPressure range0...250 bar
PS311-16V-09-LI2UPN8-H1141Front-Flush Pressure Sensor Relative pressure: -1 … 16 bar100001546Communication protocolIO-LinkElectrical outputSwitching output, Current output (3-wire), Voltage output (3-wire), IO-LinkProcess connectionG 1/2″ male thread, front-flushPressure range-1...16 bar
PS311-25V-09-LI2UPN8-H1141Front-Flush Pressure Sensor Relative pressure: -1 … 25 bar100001557Communication protocolIO-LinkElectrical outputSwitching output, Current output (3-wire), Voltage output (3-wire), IO-LinkProcess connectionG 1/2″ male thread, front-flushPressure range-1...25 bar
PS510-40V-08-LI2UPN8-H1141Pressure sensor Relative pressure: -1 … 40 bar100001563Communication protocolIO-LinkElectrical outputSwitching output, Current output (3-wire), Voltage output (3-wire), IO-LinkProcess connectionG 1/2″ male thread DIN 3852-E (manometer)Pressure range-1...40 bar
PS510-250-08-LI2UPN8-H1141Pressure sensor Relative pressure: 0 … 250 bar100001583Communication protocolIO-LinkElectrical outputSwitching output, Current output (3-wire), Voltage output (3-wire), IO-LinkProcess connectionG 1/2″ male thread DIN 3852-E (manometer)Pressure range0...250 bar